The construction of the sewer line through the room

Hello.

Is it possible to place a guest toilet at one end of the room if the sewer box is at the other end. Is it possible to pipe them through the entire room?

Arthur

Expert Answer

Hello Arthur.

Why not? A similar scheme works even when the riser is on a wall perpendicular to the toilet discharge plane, that is, when the line passes with a 90-degree turn. If a branch without bends will be used, then it is enough to make a minimum bias. The situation is even more simplified when installing the installation - in this case, a difference in elevation will contribute to a good drainage of wastewater.

For the construction of a sewer branch from the toilet to the riser, it is recommended to use a pipe with a diameter of at least 100 mm - in this case, it will be possible not only to avoid blockages, but also to prevent the stagnation of the water shutter. The slope, which must be observed at the same time, is at least 10-20 mm per 1 linear meter of the line. If such a condition is not feasible in your situation, then the toilet can be installed on the podium. Or, as a way out, install a modern installation system. We hope our tips will help you make your home as comfortable and reliable as possible. If you still have questions, we will be happy to answer them.

 

 